Original Issue Date: 2/17
Model: 5- -10EKD/4- -8EFKD, 6EKOD/5EFKOD, 9- -11EKOZD/7- -9EFKOZD
Market: Marine
Subject: Two-Inch (NMEA 2000) Digital Gauge Kit GM96999-KP1
Introduction
The remote two-inch digital gauge has controls that
allow starting, stopping, resetting select faults, and
monitoring of generator set functions The two-inch
remote digital gauge can be used with the marine
generator models/controllers shown in Figure 1. See
Figure 2 for the remote digital gauge.
Model
Controller
5--10EKD
4--8EFKD
6EKOD
5EFKOD
9--11EKOZD
7--9EFKOZD
Figure 1 Kit Number for Model with Controller Type
4
1. START (up) arrow button
2. MODE button
3. STOP (down) arrow button
4. LCD display
Figure 2 Gauge Pushbuttons
The gauge communicates with the generator set
model(s) listed above. A 12-pin customer-interface
connector allows connection from the gauge to the
generator set.
Note: Read the entire installation procedure including
safety precautions before beginning installation.
Perform the steps in the order shown.
INSTALLATION INSTRUCTIONS
Kit Number
ADC II
GM96999-KP1
ADC IId
The current software versions are located in TechTools
on the Kohler Power Resource Center. Access the
TechTools site to update the controller software to the
version indicated in Figure 3.
Model
5--10EKD
4--8EFKD
6EKOD
5EFKOD
9--11EKOZD
7--9EFKOZD
Figure 3 Controller Software Updates
Safety Precautions
Observe the following safety precautions while installing
and operating the gauge.
1
2
3
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
Disabling the generator set.
cause severe injury or death.
generator set or equipment connected to the set, disable the
generator set as follows: (1) Move the generator set master
switch to the OFF position. (2) Disconnect the power to the
battery charger. (3) Remove the battery cables, negative (--)
lead first.
Reconnect the negative (--) lead last when
reconnecting the battery. Follow these precautions to prevent
starting of the generator set by an automatic transfer switch,
remote start/stop switch, or engine start command from a
remote computer.
TT-1715
Controller
Software Version
ADC II
1.8.4
ADC IId
4.4.0
WARNING
on
the
generator
set.
Accidental starting can
Before working on the
2/17

Advertisement

loading

Summary of Contents for Kohler 5-10EKD

  • Page 1 Subject: Two-Inch (NMEA 2000) Digital Gauge Kit GM96999-KP1 Introduction The current software versions are located in TechTools on the Kohler Power Resource Center. Access the The remote two-inch digital gauge has controls that TechTools site to update the controller software to the version indicated in Figure 3.
  • Page 2: Parts List

    WARNING WARNING Explosion. Carbon monoxide. Gasoline vapors cause cause severe nausea, explosion and severe injury or fainting, or death. death. exhaust system must Before starting the generator set leakproof and routinely inspected. engine, operate the blower 4 minutes and check the engine compartment Carbon monoxide symptoms.
  • Page 3 Install the remote digital gauge. Consider the following when mounting the remote digital gauge: A dry location in the wheelhouse or bridge. The wiring harness length. The mounting depth and overall size. See Figure 4 for the gauge mounting dimensions. Note: Dimensions are in mm [in.] and not to scale.
  • Page 4 For Units with an ADC II Controller GM47635-E For Units with an ADC IId Controller GM33846-E Figure 6 Remote Two-Inch Digital Gauge Diagram Shown on Sound Shielded Unit Shown on Non Sound Shielded Unit 1. Remote interface connector Figure 7 Remote Customer Interface Connector, Typical TT-1715 2/17...
  • Page 5: Configuration Mode

    Configuration Mode Use rubber grommets and cable ties as necessary to protect and secure the wiring from sharp objects, exhaust system, water, and any moving The configuration mode can be selected from any other parts. mode by pressing and holding the MODE button for 5 seconds.
  • Page 6: Fault Codes

    Unit Configuration Procedure Press and hold the MODE button for 5 seconds to enter the configuration menu. Press the MODE button again to prompt—SAE— for English or —EURO— for Metric unit selection. Units displayed in English will show temperature in Fahrenheit ( F) and pressure in psi (pounds per square inch).
  • Page 7 The normal mode will display only the following parameters when the generator set is NOT running: Hours Battery Voltage Among the status parameters is an indicator shown as an asterisk used to indicate when the generator set is running. This generator running indicator is located on hours screen shown...
  • Page 8 Generator Start/Stop If the generator was successfully stopped, the gauge will go into the normal mode and display the HRS Read all equipment decals located on the characters (hours screen) and will not display the generator set and safety precautions found in the blinking asterisk segments;...
  • Page 9 12. Using the SLEEP function 15. GEN START Fault Codes The controller automatically sends a sleep command to The normal mode can function if a fault WARN code the gauge after 48 hours of inactivity. When the off appears on the gauge; however, it will remain disabled if button is depressed, the gauge will immediately go into an ERR code appears.
  • Page 10 Digital ADC II Gauge Display Display Description — No faults Fault TPS input hi Shutdown: Throttle Position Sensor Input High Fault TPS range hi Shutdown: Throttle Position Sensor Range High Fault TPS range lo Shutdown: Throttle Position Sensor Range Low Fault TPS input lo Shutdown: Throttle Position Sensor Input Low Overload...
  • Page 11 Digital ADC II Gauge Display Display Description ECT input lo Warning: Coolant Sensor Input Low WARN Fault O2 input hi Shutdown: Oxygen Sensor Input High Fault O2 input lo Shutdown: Oxygen Sensor Input Low Fault Coolant loss Shutdown: Sea Pump Pressure Fault Over speed Shutdown: Engine Overspeed Fault Hi eng temp...
  • Page 12 Digital ADC II Gauge Display Display Description Not available Warning: Check Engine Maintenance Required WARN Fault Check engine Shutdown: Check Engine (shutdown level) WARN * Not available Unknown/Not Supported Warning ERR * Not available Shutdown: Unknown/Not Supported Shutdown 1000 Not available ECU Data Loss (generated by gauge) ERR * 1001...
  • Page 13 Digital ADC IId SiteTech Gauge Display Display Display Description — No faults Oil Pres Low Shutdwn Low Engine Oil Pressure Shutdown: Low Oil Pressure Oil Pres Low Warning Low Engine Oil Pressure Warning: Low Oil Pressure WARN Lo Crank Vlt Warning Low Cranking Voltage Warning: Weak Battery WARN...
  • Page 14 Notes TT-1715 2/17...
  • Page 15 Notes TT-1715 2/17...
  • Page 16 Singapore 619159 KOHLERPower.com Phone (65) 6264-6422, Fax (65) 6264-6455 Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator set distributor for availability.

This manual is also suitable for:

4-8efkd6ekod5efkod9-11ekozd7-9efkozd