Genset Information; Genset Run Time; Genset System - Kohler 6EKOD Service Manual

Marine generator sets
Hide thumbs Also See for 6EKOD:
Table of Contents

Advertisement

7.13.5 GenSet Information

Displays generator set and controller information.
Displayed data is factory entered.
GenSet Information
GenSet ---->
Information

7.13.6 GenSet Run Time

Displays the generator set's operating record including
total run time loaded and unloaded, number of starts,
and total energy kW hours.
GenSet Run Time
GenSet ---->
Run Time

7.13.7 GenSet System

Display shows the generator set system data. Use the
values entered in this menu to help determine shutdown
values and time delays.
The programming user defines the data shown in the
GenSet System menu. It is NOT data measured by the
controller and associated sensing devices.
programming user defines these values for purposes of
calibrating the control.
Some alternators are designed to operate at limited
voltage, frequency, or phase connections and as a result
some settings may have limited parameters.
TP-6774 2/14a
Genset M/N:
##
GenSet S/N:
##
Cntrllr S/N:
##
Eng Runtime:
##.# h
Eng Starts:
#
Next Maint:
##.# h
Since Maint:
## Starts
The
Display for Measurement System is user selectable as
English or Metric.
Contrast display is user adjustable to help improve
digital display visibility in dimly lit rooms or in direct
sunlight.
Note: The contrast feature is a controller hardware
change and may not be available on older units
even if the firmware is updated.
To enable editing of "GenSet System" parameters:
1. At the "GenSet System" menu, press the selector
dial and rotate until "System Freq" appears.
2. Press and hold the selector dial until "Editing
Enabled" appears.
3. Scroll through the parameters and press the
selector dial at the parameter that requires
changing. The parameter blinks to indicate that it is
editable.
4. Press the selector dial to change the parameter.
Note: Parameters automatically scroll and keep
blinking until the desired selection is made by
pressing the selector dial.
5. Select "Return" to return to the "GenSet System"
menu.
Note: After changing the CAN A communication
setting, power off and then power on the
controller.
GenSet System
GenSet ---->
System
User Selectable - ->
User Selectable - ->
User Selectable - ->
User Selectable - ->
System Freq:
60 Hz or 50 Hz
Battery V:
## V
CAN A:
J1939, SmartCraft, or
NMEA 2000
Meas System
English or Metric
Contrast
#####
Section 7 Controller
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9-11ekozd5efkod7-9efkozd

Table of Contents