7.3 SiteTecht Software

The following items are necessary PC requirements for
using the SiteTecht software.
SiteTecht Software Version 3.0 or higher by
D
accessing TechTools to download on your PC hard
drive or disk if not already installed on your PC.
TP-6701 SiteTecht Software Operation Manual
D
available by accessing TechTools.
USB Cable with a male USB-A connector on the PC
D
side and a male standard B connector on the
controller side.
7.4 Controller Service
Replacement Kit GM83745
If the troubleshooting procedures in Section 6 identify a
faulty controller, use the procedure in this section for
controller replacement. Always check the controller
configuration, fuse, wiring, and connections before
replacing the controller.
After replacing the controller, verify that the new
controller's configuration settings match the generator
set system voltage and frequency, battery voltage, and
communications settings. Refer to Section 7.13 for
instructions to check the controller configuration and to
change the settings, if necessary.
After the controller configuration has been checked and
set to match the generator set, use a voltmeter to check
the generator set output voltage. If the output voltage or
frequency
needs
adjustment,
adjustment procedure in Section 7.10.4 and 7.13.8 and
the governor adjustment instructions in Section 4.4.
TP-6774 2/14a
use
the
voltage
ADC IId Controller Replacement Procedure
1. Push the generator set power button OFF.
2. Disconnect power to the battery charger, if
equipped.
3. Disconnect the generator set engine starting
battery, negative (--) lead first.
WARNING
Accidental starting.
Can cause severe injury or death.
Disconnect the battery cables before
working
on
Remove the negative (--) lead first
when disconnecting the battery.
Reconnect the negative (--) lead last
when reconnecting the battery.
Sound Shield Equipped Models: For access to the
generator set to perform regular maintenance, remove
the sound shield doors and roof.
4. Sound-Shielded Models: Open the service-side
door.
5. Sound-Shielded Models: Release the two wing
nuts located underneath the roof. See Figure 7-3.
6. Sound-Shielded Models: Lift up the roof.
7. Sound-Shielded Models: Slide the roof towards
the service side of the unit for removal.
8. Sound-Shielded Models: Open the front, rear,
and non-service side doors as needed.
the
generator
set.
Section 7 Controller