Warnings
Code
Description
AC Sens
Loss of AC
Loss
voltage warning
Warning
occurs when the
controller does
not detect the
nominal generator
set AC output
voltage after
crank disconnect.
Battery High
High battery
Warning
voltage warning.
The fault condition
clears when the
battery voltage
returns to a
voltage within the
limits.
Battery Low
Low battery
Warning
voltage warning.
The fault condition
clears when the
battery voltage
returns to a
voltage within the
limits.
Coolnt Temp
High coolant
High
temperature
Warning
warning.
Low Crank
Low cranking
Vlt Warning
voltage warning.
Oil Pres Low
Low engine oil
Warning
pressure warning.
Figure 7-15 Advanced Digital Control IId Warnings
TP-6774 2/14a
Sensing
State(s)
Mechanism
Detected
Frequency
Post starting
over AC
aid, running,
voltage
cooldown
Analog input
Auto, fault,
start delay,
ECM start,
starting aid,
cranking,
crank pause,
post starting
aid, running,
cooldown
Analog input
Auto, fault,
start delay,
ECM start,
starting aid,
cranking,
crank pause,
post starting
aid, running,
cooldown
Analog
Post starting
aid, running,
cooldown
Analog input
Cranking
Analog
Post starting
aid, running,
cooldown
Inhibit
Delay
Time
Time
Trip Point Check
10 sec
1 sec
AC voltage
is below
5% of the
trip point for
low AC
voltage
fault/
shutdown
0 sec
10 sec
Battery
voltage
exceeds
125% of
the nominal
system
voltage
(12 V)
0 sec
90 sec
Battery
voltage is
at or below
100% of
the nominal
system
voltage
(12 V)
15 sec
5 sec
Coolant
temperature
at or above
105_ C
(221_ F)
0 sec
6 sec
Battery
voltage
drops
below 60%
of the
nominal
system
voltage
(12 V)
1 sec
10 sec
At or below
138 kPa
Check for loose connections.
Check all AC leads connected to the
controller for continuity.
Alternator excitation failure:
Inspect the brushes
(6EKOD/5EFKOD) and check the
FN and FP connections.
Contact an authorized
distributor/dealer for service.
Check the battery rating and
condition.
Check the battery charger
operation.
Check the battery rating and
condition.
Charge or replace the battery.
Check the battery charger
operation.
Check for a low engine coolant
level.
Check seawater system for reduced
flow.
NOTE: Allow the generator set to
cool down before checking.
Check the battery rating and
condition.
Charge or replace the battery.
Check for leaks in the lubrication
system.
Check the oil level and add oil if the
level is low.
Section 7 Controller