SiBE04-809
2.5
Removal of
Procedure
Step
1. Remove the peripheries.
1
Remove the electronic
expansion valve coil.
2
Remove the
terminal
cover.
Removal Procedure
Four Way Valve
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Terminal cover
Red (U)
Yellow (V)
Blue (W)
Points
(R7233)
Remove the four way valve
and the sheets of putty so as
not to burn them.
Be careful so as not to burn
the compressor terminals or
the name plate.
(R7234)
Make a note.
(R7235)