SiBE04-809

1.12 Removal of Fan Rotor and Fan Motor

Procedure
Step
1. Remove the right side
plate.
Loosen the 2 screws.
1
Remove the right side
2
plate.
2. Remove the motor cover.
Loosen the 2 screws
1
and remove the motor
cover.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure