Service Check Function
3.
Service Check Function
In the
indicate corresponding codes.
Check Method 1
1. When the timer cancel button is held down for 5 seconds, a " 00 " indication flashes on the
2. Press the timer cancel button repeatedly until a continuous beep is produced.
Note:
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code
74
ARC433
series
remote
temperature display section.
The code indication changes in the sequence shown below, and notifies with a long beep.
No.
Code
00
1
U4
2
L5
3
E6
4
H6
5
H0
6
A6
7
E7
8
U0
9
F3
10
A5
11
display also cancels itself if the button is not pressed for 1 minute.
controller, the temperature display sections on the main unit
TIMER CANCEL button
<
>
ARC433B41
No.
Code
F6
12
C7
13
A3
14
H8
15
H9
16
C9
17
C4
18
C5
19
J3
20
J6
21
E5
22
SiBE04-809
(R8358)
No.
Code
A1
23
E1
24
UA
25
UH
26
P4
27
L3
28
L4
29
H7
30
U2
31
EA
32
AH
33
Service Diagnosis