Utility mode
6
Touch the button for the paper tray to be set.
7
Press the [Start] key.
Only paper loaded into the bypass tray can be used.
A test pattern is printed.
8
Check that the distance from the starting print position of the test pattern to the edge of the paper (b)
is 3 mm (±0.5 mm).
If the distance is 2.4 mm or less, touch [+] to increase the adjustment (between 0.2 mm and 3.0 mm).
If the distance is 3.6 mm or more, touch [-] to reduce the adjustment (between -0.2 mm and -3.0
mm).
If the distance is between 2.5 mm and 3.5 mm, continue with step 10.
Each time [+] or [-] is touched, the value is increased
or decreased by one increment.
9
Press the [Start] key.
The adjusted test pattern is printed.
10
Adjust the distance from the starting print position of the test pattern to the edge of the paper.
Check that the distance has been adjusted to between 2.5 mm and 3.5 mm.
If more adjustment is necessary, repeat steps 8 and 9.
To adjust the print position for a different paper tray, return to step 6.
11
Touch [OK].
To cancel the setting and select the default, press the [Reset] key.
The print position is adjusted.