Figure 5-29 Data Key Function Assignment
Assigning Data Functions to Configurable Panel Keys - PNet panel keys are categorized into
four distinct sections – Level Keys (always keys 1 thru 8), Source Keys and Destination Keys.
The fourth category is the function keys for Take, Preset and Lock/Protect operations; these are
fixed on every panel type.
Below the name and type fields you will see a list field with a column labeled Key # on the left-
hand side. The numbers in the key # column correspond to the number assigned to each key of
the panel as depicted by the on-screen graphic. You may click in any cell of the key row to
highlight the data entry fields.
On the right-hand side of the screen you will see three scroll lists for Sources, Destinations and
Levels. Each Key # entry in the list can be assigned to only one type of function, and when you
highlight any key row, only the selection box for the function type that is valid for the selected
key will be active, and the remaining two boxes will appear muted with a gray foreground.
For example, refer to Figure 5-29 and you will see that the row for Key # 1 is highlighted and
the entries indicate that this key is assigned to the switching level (LEV) named VIDEO. Notice
that with Key# 1 row highlighted, only the selection box for Levels is active and the Source
(Src) and Destination (Dest) lists are shown as muted. This indicates that Level is the only valid
function for the key, and that neither a source nor destination assignment may be made to it.