If you choose a starting field from the name columns of the grid, and you do include numerical entry
fields under the switching level columns when defining the fill block, as shown below, the text entry of
the name will be duplicated in each field of the defined block, and the numerical value associated with
the name will be incremented by one in each successive field of the fill block. All of the numerical
values in the switching level columns included in the data block will be incremented by one in each
successive field, as shown. Numerical fields NOT included in the defined data block will be filled with
zeros.
There are a couple of rules you need to be aware of when using the copy and increment function:
The fill block you define with the mouse must include at least one of the name columns, and the
name entry in the starting field must end in a numerical value, such as DEMOD1, DEMOD2,
etc.
Numerical values under any of the switching level columns will be incremented by one up to
the maximum number of physical inputs or outputs defined for the level. If the fill block
contains additional lines after any level column reaches the maximum number, any successive
fields in that column will be filled with zeros.
Auto Increment
The Auto Increment function increments the numerical value of a starting entry into the fields of a user-
defined fill block located below and in the same column as the starting entry. You must choose a
starting field from a numerical entry field in any of the switching level columns when defining the fill
block, as shown by the diagram below. Numerical values in the selected column will be incremented by
one in each successive field, as shown. The Auto Increment function will only add numerical values if
every line of the fill block already has a name, such as assigned to a source or destination, associated
with the level.
Numerical values under the selected switching level column will be incremented by one up to the
maximum number of physical inputs or outputs defined for the level. If the fill block contains additional
lines after any switching level column reaches the maximum number, any successive fields in that
column will be filled with zeros.