2-3-4. Switches on the Card

Do not access internal cards or make connections with the unit powered ON. Always
power OFF all connected units / disconnect power cords prior to accessing the interior.
Further note that adjustments and maintenance should only be performed by qualified
technical personnel familiar with FOR-A equipment.
Remove two screws on both sides of the MFR-GPI to access the internal card as shown
below. The figure below shows the factory default switch settings.
Switch
S2, S3
Used for maintenance. Do not use.
Used for maintenance. Do not use. (The factory
S4
default setting is as shown at right. The black
boxes (■) represent switches.)
Used for IP address setting.
S5,S6,S7,
S8,S9,S10
S11
Used for maintenance. Do not use.
S12, S14
Used to select RS-232C/RS-422 for SERIAL 1.
Default setting is RS-422 (both switches to the
right). To change to RS-232C, set both switches
to the left.
S13, S15
Used to select RS-232C/RS-422 for SERIAL 2.
Default setting is RS-422 (both switches to the
right). To change to RS-232C, set both switches
to the left.
S16, S18
Used to select RS-232C/RS-422 for SERIAL 3.
Default setting is RS-422 (both switches to the
right). To change to RS-232C, set both switches
to the left.
S17, S19
Used to select RS-232C/RS-422 for SERIAL 4.
Default setting is RS-422 (both switches to the
right). To change to RS-232C, set both switches
to the left.
CAUTION
S11
ON
OFF
S5
S6
S7
S8
S9
S10
232C
232C
Function / Settings
29
S17
S16
S13
S12
S2
422
232C
422
232C
422
232C
422
232C
232C
422
S19
S18
S15
S14
S3
422
232C
422
232C
422
232C
422
232C
232C
422
RS-232C
(Factory
default
setting)
Switch
Settings
RS-422
422
422
Front
ON
OFF
ON
OFF