5.6.1.1

Configuration

COM port emulation on the next free COM address with 38400 baud,
8 data bits, 1 stop bit, no parity and a CR as suffix.
Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with
an acoustic signal.

5.7 Activating the read process

To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface
(COM port emulation only). The command is to be sent at the set baud rate, parity, and data and stop bits.
The activation command is:
To cancel read readiness, send a deactivation.
The deactivation command is:
Following a successful read operation, the IT 1911i deactivates itself.
The second option is to use the trigger button to establish read readiness.
5.8 Configuration
Further details on configuration, such as parameters for code type release, number of digits, etc., can be
found in the User's Guide IT 1910i/1911i.
Leuze electronic
SYN T CR
SYN U CR
IT1911i
ASCII decimal values: 022; 084; 013
ASCII decimal values: 022; 085; 013