Leuze electronic IT 1910i Technical Description
Leuze electronic IT 1910i Technical Description

Leuze electronic IT 1910i Technical Description

Industrial 2d-code hand-held scanner
Hide thumbs Also See for IT 1910i:

Advertisement

Quick Links

IT 1910i
Industrial 2D-code hand-held scanner
TECHNICAL DESCRIPTIO N

Advertisement

Table of Contents
loading

Summary of Contents for Leuze electronic IT 1910i

  • Page 1 IT 1910i Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTIO N...
  • Page 2 © 2013 Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Phone: +49 7021 573-0 Fax: +49 7021 573-199 http://www.leuze.com info@leuze.de...
  • Page 3: Table Of Contents

    IT 1910i to MA 21 ..........................16 IT 1910i to PS2 interface ........................17 IT 1910i to USB interface (keyboard emulation) ................18 IT 1910i to USB interface (COM port emulation) ................19 Activating the read process ....................... 20 Configuration ............................. 20 Troubleshooting ..........................
  • Page 4 Connecting to Leuze multiNet Plus ....................24 Connection to various fieldbuses using MA 200i ................24 Service and support ........................25 Leuze electronic IT1910i...
  • Page 5: Scope Of Delivery

    Scanner reading field Type designation Information about standards 1.1 IT 1910i xx 1. Hand-held scanner IT 1910i xx 2. Package insert An overview of the types can be found on page 22. For accessories, see page 23. Leuze electronic IT1910i...
  • Page 6: Installation

    Make sure that the PC is switched off before connecting the scanner. 2.1.2 Connecting the IT 1910i 1. To secure the connection cable to the scanner, proceed as follows: Insert the RJ 41 connector into the socket on the bottom of the hand-held scanner, close the cord grip and secure it using the screw.
  • Page 7: How Do I Scan Codes

    2.2.1 Testing the scanner The adjacent bar code can be used for testing the scanner, the module size is 0.5 mm (20 mil) Code 39 bar code sample Leuze electronic IT1910i...
  • Page 8: Technical Data

    3 Technical Data The technical data can be found in the data sheet for the IT 1910i. 3.1 Pin assignments of the connection cable 3.1.1 KB 232-1 IT 190x Part no. 50114517 Helix cable, maximum length 3 m. Signal level 0 and +5 volts TTL...
  • Page 9: Kb Usb-1 It 190X Part No. 50114521

    KB USB-2 IT 190x Part no. 50114523 Pin assignments of USB type A connector for cable CBL-500-500-C00: as with part no. 50114521, but helix cable, maximum length 5 m. 3.2 Reading fields IT 1910i ER-3 5 mil Code 39 (0.127 mm) 13 mil (0.330 mm)
  • Page 10: Resetting The It 1910I To Factory Settings

    4 Resetting the IT 1910i to factory settings To reset all parameters to factory settings, scan the bar code shown below. Attention! All settings are lost! Leuze electronic IT1910i...
  • Page 11: Configuration

    The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time. The standard applications are described and summarized below. Leuze electronic IT1910i...
  • Page 12: 1910I To The Serial Pc Interface

    5.1.1 With KB 232-1 IT190x Part no. 50114517 For pin assignments, see chapter 3.1.1. 5.1.2 With voltage supply via PIN 9 Please connect the IT 1910i acc. to the adjacent figure. Required parts: 50122436 IT 1910i ER-3 50114517 KB 232-1 IT190x RS 232 transmission with 115200 baud, 8 data bits, 1 stop bit, no parity, no prefix and suffix.
  • Page 13: With Voltage Supply Via Power Supply Unit

    5.1.3 With voltage supply via power supply unit Please connect the IT 1910i acc. to the figure below. Required parts: 50122436 IT 1910i ER-3 50114517 KB 232-1 IT 190x 50114525 Power supply unit RS 232 transmission with 115200 baud, 8 data bits, 1 stop bit, no parity, no prefix and suffix.
  • Page 14: 1910I To Ma 200I

    Open the MA 200i • Guide KB JST-HS-300 with the PG cable gland through the threaded hole and insert the 12-pin JST connector Connect the IT 1910i with the RS 232 cable • • Connect the cable to the 9-pin D-sub connector •...
  • Page 15 IT1910i KB JST-HS-300 approx. 0.3 m 9-pol. D-sub 18 to 30 V DC Details on connecting the MA 200i can be found in "Technical description MA 200i". 5.2.1.1 Configuration Data transmission to MA 200i Leuze electronic IT1910i...
  • Page 16: 1910I To Ma 21

    5.3 IT 1910i to MA 21 RS 232 transmission with 9600 baud, 7 data bits, 1 stop bit, even parity, suffix CR/LF. Required parts: 50122436 IT 1910i ER-3 50114517 KB 232-1 IT190x 50035421 KB 021 Z 50030481 MA 21 100 5.3.1.1...
  • Page 17: 1910I To Ps2 Interface

    5.4 IT 1910i to PS2 interface The operation of the IT 1910i in keyboard-wedge mode is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program.
  • Page 18: 1910I To Usb Interface (Keyboard Emulation)

    5.5 IT 1910i to USB interface (keyboard emulation) The operation of the IT 1910i in keyboard-wedge mode on a USB port is described in this chapter. A PC keyboard is emulated in this operating mode. The data which are read in are written directly to the currently activated program.
  • Page 19: 1910I To Usb Interface (Com Port Emulation)

    5.6 IT 1910i to USB interface (COM port emulation) The operation of the IT 1910i as a serial interface on a USB port is described in this chapter. A COM interface is emulated in this operating mode. The data which are read in are sent to a new COM interface. The driver with which you emulate this COM interface can be downloaded from our homepage at www.leuze.com.
  • Page 20: Activating The Read Process

    ASCII decimal values: 022; 085; 013 The deactivation command is: SYN U CR Following a successful read operation, the IT 1910i deactivates itself. The second option is to use the trigger button to establish read readiness. 5.8 Configuration Further details on configuration, such as parameters for code type release, number of digits, etc., can be found in the User's Guide IT 1910i/1911i.
  • Page 21: Troubleshooting

    If you suspect that the problem lies with the quality of the label, check the read readiness with a label of relatively good quality. 8. If the problems are still not corrected, please contact the Leuze electronic hotline (see chapter 8). Leuze electronic...
  • Page 22: Type Overview

    Interface Figure Hand-held reader for bar codes and 2D-codes (extended range) 50122436 IT 1910i ER-3 PS2 / USB / TTL RS 232 All devices are supplied without cable. Cables must be ordered separately; see chapter "7 Accessories/Spare parts". Leuze electronic...
  • Page 23: Accessories/Spare Parts

    50114521 CBL-500-300-S00 USB cable for IT 190x straight KB USB-2 IT 190x 50114523 CBL-500-500-C00 USB cable for IT 190x spiral KB 232-1 IT 1910i 3 m 50114517 CBL-020-300-C00 RS 232 cable for IT 190x spiral KB 232-2 IT 1910i 3 m 50115105...
  • Page 24 • MA 21 100 Interface converter / multiNet plus Part no. 50030481 • KB 021 Z Connection cable MA xx to IT 1910i Part no. 50035421 7.2 Connection to various fieldbuses using MA 200i Profibus gateway Part no. 50112893 •...
  • Page 25: Service And Support

    Monday to Thursday 8.00 a.m. to 5.00 p.m. (UTC+1) Friday 8.00 a.m. to 4.00 p.m. (UTC+1) E-mail: service.identify@leuze.de Return address for repairs: Service center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Leuze electronic IT1910i...