IT 1911i to USB interface (COM port emulation) ................21 Activating the read process ....................... 22 Configuration ............................. 22 Troubleshooting ..........................23 Type overview ..........................24 Accessories/Spare parts ........................ 25 Connecting to Leuze multiNet Plus ....................26 Connection to various fieldbuses using MA 200i ................26 Leuze electronic IT1911i...
Page 4
Service and support ........................27 Leuze electronic IT1911i...
2. Rechargeable battery (installed) 3. Package insert Information about standards 1.2 Base station IT 1911i 1. Base station CCB02-100BT Type designation Information about standards An overview of the types can be found on page 24. For accessories, see page 25. Leuze electronic IT1911i...
4. Connect the power supply unit to the power socket. 5. Configure the hand-held scanner using the codes for the corresponding application; see chapter "5 Configuration" or the external document "User’s Guide IT 1910i/1911i". Leuze electronic IT1911i...
2.3.1 Testing the scanner The adjacent bar code can be used for testing the scanner, the module size is 0.5 mm (20 mil) Code 39 bar code sample Leuze electronic IT1911i...
Straight cable, maximum length 3 m. Pin assignments of USB type A connector for cable CBL-500-300-S00 USB type A connector Signal Designation VCC IN 5 Volts DC Data - Data line - Data - Data line + Ground connection Leuze electronic IT1911i...
13 mil (0.330 mm) 20 mil Code 39 (0.508 mm) 6.7 mil PDF 417 (0.170 mm) 10 mil Data Matrix (0.254 mm) 20 mil QR Code (0.508 mm) Typ. reading distance [mm] 1) Dependent on code module Leuze electronic IT1911i...
Return the IT 1911i to the base station so that the settings can be accepted. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. You may then continue making settings or operation of the device. Leuze electronic IT1911i...
The program can be used to make settings and transfer them to the hand-held scanner. The configuration can also be stored so that it can be reused at a later time. The standard applications are described and summarized below. Leuze electronic IT1911i...
RS 232 transmission with 115200 baud, 8 data bits, 1 stop bit, no parity, suffix CR/LF. Return the IT 1911i to the base station so that the settings can be accepted. Successful reading is confirmed by an acoustic signal and the red LED on the base station going out briefly. Leuze electronic IT1911i...
The individual pieces of bar code information are again provided in succession in the Aztec configuration code. Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i...
Connect the RS 232 cable to the 9-pin D-sub connector • Set the address using the address switch • Insert the field bus connection cable • Apply the voltage supply. Please connect the base station acc. to the following figure. Leuze electronic IT1911i...
Page 15
KB JST-HS-300 approx. 0.3 m 9-pol. D-sub 18 to 30 V DC Details on connecting the MA 200i can be found in "Technical description MA 200i". NOTICE You can find the configuration codes on the next page. Leuze electronic IT1911i...
Page 16
The individual pieces of bar code information are again provided in succession in the Aztec configuration code. Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i...
Power supply unit 50035421 KB 021 Z 50030481 MA 21 100 5.3.1.1 Pin assignments KB021 Z Core color Signal Terminal assignments MA 21 brown (RXD) white (TXD) blue (GND) (VCC) black (GND) bare (shield) (PE) Leuze electronic IT1911i...
Page 18
The individual pieces of bar code information are again provided in succession in the Aztec configuration code. Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i...
5.4.1.1 Configuration PS2 keyboard emulation with CR LF Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i...
5.5.1.1 Configuration USB keyboard emulation with CR LF Return the IT 1911i to the base station so that the settings can be accepted. This procedure is concluded with an acoustic signal. Leuze electronic IT1911i...
115200, 8 data bits, 1 stop bit and no parity. A CR is transmitted as suffix (or terminator). NOTICE To charge the IT 1911i, the power supply unit must be plugged in and the hand-held scanner placed in the base station. Leuze electronic IT1911i...
The second option is to use the trigger button to establish read readiness. 5.8 Configuration Further details on configuration, such as parameters for code type release, number of digits, etc., can be found in the User's Guide IT 1910i/1911i. Leuze electronic IT1911i...
If you suspect that the problem lies with the quality of the label, check the read readiness with a label of relatively good quality. 8. If the problems are still not corrected, please contact the Leuze electronic hotline (see chapter 8). Leuze electronic...
Base station with communication and charging function Bluetooth class 1 50122431 Base station for IT 1911i PS2 / USB / TTL RS 232 All devices are supplied without cable. Cables must be ordered separately; see chapter "7 Accessories/Spare parts". Leuze electronic IT1911i...
2000 mAh BAT-Charger-4 Desk-EU Charging station with power MB4-BAT- 50114494 1.5 m supply unit for up to 4 SCN01EUD0 straight batteries wall mount; 50120444 BT Wallholder HS65x8 11-66553-06R plastic steel rope; 50107034 Rope for IT3800i/4800/6300 ToolBalE plastic Leuze electronic IT1911i...
Profibus gateway Part no. 50112893 • MA 204i Ethernet gateway Part no. 50112892 • MA 208i Profinet gateway Part no. 50112891 • MA 248i • KB JST-HS-300 Connection cable MA xx to IT 1911i Part no. 50113397 Leuze electronic IT1911i...
Monday to Thursday 8.00 a.m. to 5.00 p.m. (UTC+1) Friday 8.00 a.m. to 4.00 p.m. (UTC+1) E-mail: service.identify@leuze.de Return address for repairs: Service center Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen / Germany Leuze electronic IT1911i...
Need help?
Do you have a question about the 1910i and is the answer not in the manual?
Questions and answers