Control Interface; 11.1.1 Navigating Through The Liebert Icom Menus; Figure 54 User Menu Icons And Descriptions - Emerson Liebert CRV User Manual

60hz 600mm wide air-cooled, water/glycol-cooled and chilled water units 300mm wide air-cooled units
Hide thumbs Also See for Liebert CRV:
Table of Contents

Advertisement

11.1

Control Interface

When the buttons on the Liebert iCOM
backlight turns Off. Pressing any key will wake up the screen and display the Status menu of the last
cooling unit viewed. The Status menu will show the cooling unit's operational mode(s), return air
temperature and humidity readings, temperature and humidity setpoints and any active alarms.
Whether the cooling unit is in a Liebert iCOM U2U network or is a stand-alone unit, the Status menu
will display only that cooling unit's information. Any large display connected to a network can be used
to view any cooling unit on the network or to show an average view of the entire system of cooling
units (the system view is obtained by pressing the Right and Left arrow key from the unit view). The
unit information being viewed is displayed in the upper right corner of the screen (see Figure 57 for
an example).

11.1.1 Navigating Through the Liebert iCOM Menus

User Menus
The Liebert iCOM shows icons and text for monitoring and controlling Liebert cooling units or
network of cooling units. The control is broken out into three major menus. User, Service and
Advanced menus.
The User menu contains the most frequently used features, settings and status information. See
Figure 54 for a menu overview.

Figure 54 User menu icons and descriptions

USER MENUS
°C / °F
% RH
SET
!
ACTIVE
ALARMS
°C / °F
% RH
SET
Setpoints
Spare Part List
View and
Displays the
change
various part
temperature
numbers of the
and humidity
components/par
setpoints
ts in the cooling
unit
!
ACTIVE
ALARMS
Sensor Data
Active Alarms
Shows readings
Allows the user
of standard and
to view all
optional
current active
sensors
alarms
®
Liebert
CRV
control have not been pressed for a short period, the display
®
EVENT
LOG
1 2
9
3
1 2 3 4 h
6
SET
EVENT
LOG
Event Log
Contains last
Displays temperature
400 events
and humidity graphs
1 2
9
3
SET
6
Display Setup
Total Run Hours
Change settings
Records the run time
for display:
of all components and
language, time,
allows setting
simple or
of limits on run time
graphic view
SET
ALARMS
Graphics
View Network
Shows status of all
connected units
1234h
Service Contact Info
Contains key contact
information for local
service, including
names and phone
numbers
82
®
Liebert iCOM
Control
SET
ALARMS
Set Alarms
Allows enable, disable
and settings for alarms
Condenser Timer
Contains key
information about the
Liebert MC Condenser
operation

Hide quick links:

Advertisement

Table of Contents
loading