Control Interface-Three Main Menus; Figure 5 Liebert Icom Default Home Screen—Simple View - Emerson Liebert Challenger 3000 Operation & Maintenance Manual

Precision cooling for business-critical continuity
Hide thumbs Also See for Liebert Challenger 3000:
Table of Contents

Advertisement

Figure 5
Liebert iCOM default home screen—Simple view
Return Air
Temperature
Setpoint
System or
UNIT 1
Unit # view
Temperature
74.1
Sensor Reading
Evaporator
Fan Speed
100%
Percent
Cooling
9/29/2010 09 :18:07
Date and
Time
9/29/2010 08 :28 (01) MSG UNIT ON
9/29/2010 08 :27 (01) MSG POWER ON
for nex t / pr ev uni t
for menu
4.1.1
Control Interface—Three Main Menus
The Liebert iCOM control has three main menus: User, Service and Advanced.
The User menu contains the most frequently used features, settings and status information. The Ser-
vice menu contains settings and features used to set up unit communications and for unit mainte-
nance. The Advanced menu contains settings used to set up the unit at the factory.
NOTE
The Liebert iCOM's Advanced menu is for factory use only or in consultation with the factory
service department.
NOTE
Menu settings may be viewed without a password, but changing settings requires a password.
If a password is required, the Liebert iCOM shows a prompt to enter the password. The
password for the User menu is 1490. The password for Service menu is 5010. For details on
entering a password, see 4.1.3 - Entering the Password
When the buttons on the Liebert iCOM control have not been pressed for a short period, the display
backlight turns Off. Pressing any key will turn the backlight On (wake up the screen) and display the
Status menu of the last cooling unit viewed. The Status menu will show the cooling unit's operational
mode(s), return air temperature and humidity readings, temperature and humidity setpoints and any
active alarm conditions.
If the cooling unit has a large display and is not on a network, or if the unit has a small display,
whether it is networked or stand-alone, the Status menu will display only that cooling unit's informa-
tion. Any large display that is connected to a network can be used to view any cooling unit on the net-
work or show an average view of the entire system of cooling units.
Return Air
72.0°F
50
°F
72%
for previous screen
E S C
Liebert iCOM Display Components and Functions
Humidity
Humidity Sensor
Setpoint
Reading
50%
51.6
%
for s y s tem v i ew
? for help
10
Supply Air Setpoint
Supply
Air Temperature
52.0°F
SET
°F
ACT
Next
Maintenance
03/2011
System (or Unit)
On/Off
UNIT ON
Most Recent
Alarms
(Date, Time, Unit,
Description)