Xycom Automation produced two different TSKAM boards for the 3600 units. To
determine which TSKAM board is used with your unit check the jumper numbers
on the board.
If the TSKAM board has both JP12 and JP17 connectors present, it is TSKAM
Board 2, Part Number 142430-001/2. See Table E - 2for the jumper and switch
settings for this board.
If the TSKAM board has neither of these connectors, it is TSKAM Board 1, Part
Number 141438-001. See Table E - 1 for the jumper and switch settings for this
board.

TSKAM Board 1, Part Number 141438-001 2

Table E - 1 lists the jumper and switch settings for the TSKAM 1.
Switches/Jumpers
SW1 (1-4)
SW2 (1-4)
JP3
JP4
JP5
JP7
JP8
JP9
JP14
indicates factory default position
Table E - 1. Jumper and Switch Settings for TSKAM 1
Position/Setting
Function
All OFF
Keypad type
All OFF
Reserved
A
Connects H8 keyboard controller pin P8-4/IRQ3*
Connects H8 keyboard controller pin P8-4/IRQ3* to
B
A
Connects H8 pin P8-5 to H8 MDATA
B
Connects H8 pin P8-5 to H8 programming header
P6 pin 3
A
Connects H8 pin P8-1 to H8 MCLK
B
Connects H8 pin P8-1 to program header P6 pin 9
A
Enables H8 ROM access
B
Disables H8 ROM access
In
Connects H8 STBY* pin to program header P6 pin
11
Out
Disconnects H8 STBY* pin from program header
In
Remote switch interrupt connected to H8
Out
Remote switch interrupt not connected to H8
A
3.3V LCD Power
B
5V LCD Power
to HOST_KBDATA
programming header P6 pin 4