2.

Features and Part Names

2.1

Major Features

1. Basic functions
[Up to 384 input/output points]
The number of input/output points (up to 256
points) wired directly to the PLC and remote
input/output points (up to 256 points) on the
network (CC-Link) can be increased to 384
points in total.
[Powered extension units/blocks that can be
connected]
FX
Series input/output powered extension
2N
units/blocks can be connected.
Up to 8 FX
/FX
0N
units/blocks can be connected.
(Among FX
0N
connected.)
[Program memory]
The PLC has a 64K-step RAM memory.
Use of the memory cassette enables the
program memory to be used as flash memory.
[Operation instructions]
Various instructions, such as floating-point and
character string processing instructions and
scaling instructions, are provided.
[Built-in RUN/STOP switch]
The PLC can be started and stopped with the
built-in switch.
RUN and STOP commands can be given to the
PLC through a general-purpose input terminal or
peripheral device.
[Writing during RUN]
The
programming
computer enables you to modify the program
while the PLC is running.
[Built-in clock function]
The PLC has a clock function to control the time.
[Programming tool]
Use a version of a programming tool supporting
the FX
.
3U
→ Refer to Chapter 5 "Version Information
and Peripheral Equipment Connectability"
*For peripheral devices not applicable to FX
Series, specify FX
model selection, and you can program the
34
/FX
Series special function
2N
3U
Series, only FX
-3A can be
0N
software
for
personal
in this manual.
Series or FX
Series for
2N
2
sequence. In this case, use instructions and
devices within the ranges common to FX
Series and the selected model of PLC.
[Remote debugging of program]
Use of programming software (GX Works2, GX
Developer) enables you to remotely transfer
programs and monitor PLC operation through a
modem connected to the RS-232C expansion
board and RS-232C communication special
adapter.
2. Input/output high-speed processing
functions of main unit
[High-speed counter function]
1) Input terminals of main unit
- Input of open collector transistor output
- 1-phase 100 kHz x 6 points + 10 kHz x 2
points
- 2-phase 50 kHz x 2 points
2) Input terminals of high-speed input special
adapter (FX
- Input of differential line driver
- 1-phase 200 kHz x 8 points (when 2 units
are connected)
- 2-phase 100 kHz x 2 points (when 2 units
are connected)
→ Refer to Chapter 11 "Use of High-speed
Counters (C235 to C255)" in this manual
[Pulse catch function]
Signals with short ON width or OFF width can be
captured without a complicated program.
→ Refer to Chapter 10 "Input Wiring
Procedures (Input Interruption and Pulse
Catch)" in this manual and Programming
Input terminal
X000 to X005
X006, X007
3U
2 Features and Part Names
2.1 Major Features
-4HSX-ADP)
3U
and Programming Manual.
Manual.
Signal ON/OFF width
5µs