Mitsubishi FX3U-?*MR/ES User Manual page 482

Fx3u series programmable controllers
Table of Contents

Advertisement

FX
Series Programmable Controllers
3U
User's Manual - Hardware Edition
Number and
Operation and function
name
PLC Mode
When M8030 set to ON, LED on
*1
M 8030
PLC is not lit even if low battery
Battery LED OFF
voltage is detected.
*1
If this special auxiliary relay is
M 8031
activated,
Non-latch
memory of Y, M, S, T, and C, and
memory all clear
present values of T, C, D, special
data registers and R are cleared to
zero.
*1
M 8032
However, file registers (D) in
Latch memory
program memory, and extension
all clear
file registers (ER) in the memory
cassette are not cleared.
M 8033
When PLC is switched from RUN
Memory hold
to STOP, image memory and data
STOP
memory are retained.
*1
All external output contacts of PLC
M 8034
are turned OFF.
All outputs disable
M 8035
Forced RUN mode
→Refer to Programming Manual
M 8036
Forced RUN signal
M 8037
Forced STOP signal
[M]8038
Communication parameter setting
Parameter setting
flag (for N:N network setting)
M 8039
When M8039 is ON, PLC waits until
Constant scan
scan time specified in D8039 and
mode
then executes cyclic operation.
*1. Executed at END instruction
Step Ladder and Annunciator
M 8040
While M8040 is turned ON, transfer
Transfer disable
between states is disabled.
*2
Transfer from initial state is enabled
[M]8041
in automatic operation mode.
Transfer start
[M]8042
Pulse output is given in response
Start pulse
to a start input.
*2
M 8043
Set this in the last state of zero
Zero return
return mode.
complete
*2
Set this when machine zero return
M 8044
is detected.
Zero point condition
M 8045
Disables the 'all output reset'
All output reset
function when the operation mode
disable
is changed.
ON when M8047 is ON and either
*3
[M]8046
of S0 to S899 or S1000 to S4095 is
STL state ON
active.
*3
M 8047
D8040 to D8047 are enabled when
STL monitoring
M8047 is ON.
enable
*3
[M]8048
ON when M8049 is ON and either
Annunciator
of S900 to S999 is ON.
operate
*2
M 8049
D8049 is enabled when M8049 is
Annunciator
ON.
enable
*2. Cleared when PLC switches from RUN to STOP.
*3. Executed at END instruction.
474
Correspond-
ing special
device
the
ON/OFF
image
for details.
D8176 to
D8180
D8039
M8047
D8040 to
D8047
D8049
M8048
A Operation of Special Devices (M8000 -, D8000 -)
A-1 Special Auxiliary Relay (M8000 to M8511)
Number and
name
Interrupt Disable
M8050
(input interrupt)
*4
I00
disable
M8051
(input interrupt)
*4
I10
disable
M8052
(input interrupt)
*4
I20
disable
M8053
(input interrupt)
*4
I30
disable
M8054
(input interrupt)
*4
I40
disable
M8055
(input interrupt)
*4
I50
disable
M8056
(Timer interrupt)
*4
I6
disable
M8057
(Timer interrupt)
*4
I7
disable
M8058
(Timer interrupt)
*4
I8
disable
M8059
Counter interrupt
*4
disable
*4. Cleared when PLC switches from RUN to STOP.
Error Detection
[M]8060
[M]8061
[M]8062
*5*6
[M]8063
[M]8064
[M]8065
[M]8066
*7
[M]8067
M 8068
*8
M 8069
*5. Cleared when PLC power supply is turned from OFF to
ON.
*6. Serial communication error 2 [ch2] PLC is detected by
M8438.
*7. Cleared when PLC switches from STOP to RUN.
*8. When M8069 is ON, I/O bus check is executed.
Operation and function
• If an input interrupt or timer
interrupt occurs while a special
auxiliary relay for that interrupt
(M8050 - M8058) is ON, the
interrupt will not operate.
For example, turning M8050 ON
disables
the
I00
interrupt;
hence, the interrupt routine is not
processed even in an allowable
program area.
• If an input interrupt or timer
interrupt occurs while a special
auxiliary relay for that interrupt
(M8050 - M8058) is OFF,
a) The
interrupt
will
accepted.
b) The interrupt routine will be
processed promptly if it is
permitted by the EI (FNC
04) instruction. However, if
the DI (FNC 05) instruction
disables interrupts, the
interrupt program will not
be processed until EI (FNC
04) permits the interrupts.
Interrupt of I010 to I060 disabled
I/O configuration error
PLC hardware error
Not used
Serial communication error 1 [ch1]
Parameter error
Syntax error
Ladder error
Operation error
Operation error latch
I/O bus check
Correspond-
ing special
device
be
D8060
D8061
D8063
D8064
D8065
D8069
D8314
D8315
D8066
D8069
D8314
D8315
D8067
D8069
D8314
D8315
D8068
D8312
D8313

Advertisement