Access Point WLAN MIBs
WLAN Table
43
::= { ruckusWLANEntry 5 }
ruckusWLANDTIMPeriod OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute shall specify the number of TU that a
station shall use for scheduling Beacon transmissions.
This value is transmitted in Beacon and Probe Response
frames."
::= { ruckusWLANEntry 6 }
ruckusWLANRTSThreshold OBJECT-TYPE
SYNTAX INTEGER (256..2346)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall indicate the number of octets in an
MPDU, below which an RTS/CTS handshake shall not be
performed, except as RTS/CTS is used as a cross modulation
protection mechanism as defined in 9.10. An RTS/CTS
handshake shall be performed at the beginning of any frame
exchange sequence where the MPDU is of type Data or
Management, the MPDU has an individual address in the
Address1 field, and the length of the MPDU is greater than
this threshold. (For additional details, refer to Table 21
in 9.7.) Setting this attribute to be larger than the
maximum MSDU size shall have the effect of turning off the
RTS/CTS handshake for frames of Data or Management type
transmitted by this STA. Setting this attribute to zero
shall have the effect of turning on the RTS/CTS handshake
for all frames of Data or Management type transmitted by
this STA. The default value of this attribute shall be
2347."
::= { ruckusWLANEntry 7 }
ruckusWLANFragmentationThreshold OBJECT-TYPE