B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 35 of 48)
ADDR
REGISTER NAME
B126
IEC 61850 MMXU VAr.phsB Deadband 1
B128
IEC 61850 MMXU VAr.phsC Deadband 1
B12A
IEC 61850 MMXU VA.phsA Deadband 1
B12C
IEC 61850 MMXU VA.phsB Deadband 1
B12E
IEC 61850 MMXU VA.phsC Deadband 1
B
B130
IEC 61850 MMXU PF.phsA Deadband 1
B132
IEC 61850 MMXU PF.phsB Deadband 1
B134
IEC 61850 MMXU PF.phsC Deadband 1
B136
...Repeated for Deadband 2
B16C
...Repeated for Deadband 3
B1A2
...Repeated for Deadband 4
B1D8
...Repeated for Deadband 5
B20E
...Repeated for Deadband 6
IEC 61850 GGIO2 Control Configuration (Read/Write Setting) (64 modules)
B300
IEC 61850 GGIO2.CF.SPCSO1.ctlModel Value
B301
IEC 61850 GGIO2.CF.SPCSO2.ctlModel Value
B302
IEC 61850 GGIO2.CF.SPCSO3.ctlModel Value
B303
IEC 61850 GGIO2.CF.SPCSO4.ctlModel Value
B304
IEC 61850 GGIO2.CF.SPCSO5.ctlModel Value
B305
IEC 61850 GGIO2.CF.SPCSO6.ctlModel Value
B306
IEC 61850 GGIO2.CF.SPCSO7.ctlModel Value
B307
IEC 61850 GGIO2.CF.SPCSO8.ctlModel Value
B308
IEC 61850 GGIO2.CF.SPCSO9.ctlModel Value
B309
IEC 61850 GGIO2.CF.SPCSO10.ctlModel Value
B30A
IEC 61850 GGIO2.CF.SPCSO11.ctlModel Value
B30B
IEC 61850 GGIO2.CF.SPCSO12.ctlModel Value
B30C
IEC 61850 GGIO2.CF.SPCSO13.ctlModel Value
B30D
IEC 61850 GGIO2.CF.SPCSO14.ctlModel Value
B30E
IEC 61850 GGIO2.CF.SPCSO15.ctlModel Value
B30F
IEC 61850 GGIO2.CF.SPCSO16.ctlModel Value
B310
IEC 61850 GGIO2.CF.SPCSO17.ctlModel Value
B311
IEC 61850 GGIO2.CF.SPCSO18.ctlModel Value
B312
IEC 61850 GGIO2.CF.SPCSO19.ctlModel Value
B313
IEC 61850 GGIO2.CF.SPCSO20.ctlModel Value
B314
IEC 61850 GGIO2.CF.SPCSO21.ctlModel Value
B315
IEC 61850 GGIO2.CF.SPCSO22.ctlModel Value
B316
IEC 61850 GGIO2.CF.SPCSO23.ctlModel Value
B317
IEC 61850 GGIO2.CF.SPCSO24.ctlModel Value
B318
IEC 61850 GGIO2.CF.SPCSO25.ctlModel Value
B319
IEC 61850 GGIO2.CF.SPCSO26.ctlModel Value
B31A
IEC 61850 GGIO2.CF.SPCSO27.ctlModel Value
B31B
IEC 61850 GGIO2.CF.SPCSO28.ctlModel Value
B31C
IEC 61850 GGIO2.CF.SPCSO29.ctlModel Value
B31D
IEC 61850 GGIO2.CF.SPCSO30.ctlModel Value
B31E
IEC 61850 GGIO2.CF.SPCSO31.ctlModel Value
B31F
IEC 61850 GGIO2.CF.SPCSO32.ctlModel Value
BC20
IEC 61850 GGIO2.CF.SPCSO33.ctlModel Value
BC21
IEC 61850 GGIO2.CF.SPCSO34.ctlModel Value
BC22
IEC 61850 GGIO2.CF.SPCSO35.ctlModel Value
BC23
IEC 61850 GGIO2.CF.SPCSO36.ctlModel Value
BC24
IEC 61850 GGIO2.CF.SPCSO37.ctlModel Value
BC25
IEC 61850 GGIO2.CF.SPCSO38.ctlModel Value
BC26
IEC 61850 GGIO2.CF.SPCSO39.ctlModel Value
BC27
IEC 61850 GGIO2.CF.SPCSO40.ctlModel Value
B-42
RANGE
UNITS
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0.001 to 100
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
0 to 2
D60 Line Distance Relay
APPENDIX B
STEP
FORMAT
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
%
0.001
F003
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
DEFAULT
10000
10000
10000
10000
10000
10000
10000
10000
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
GE Multilin