GE D60 Instruction Manual page 415

Line distance relay
Hide thumbs Also See for D60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 20 of 48)
ADDR
REGISTER NAME
6801
Trip 3-Pole Input1
6802
Trip 3-Pole Input2
6803
Trip 3-Pole Input3
6804
Trip 3-Pole Input4
6805
Trip 3-Pole Input5
6806
Trip 3-Pole Input6
6807
Trip 1-Pole Input1
6808
Trip 1-Pole Input2
6809
Trip 1-Pole Input3
680A
Trip 1-Pole Input4
680B
Trip 1-Pole Input5
680C
Trip 1-Pole Input6
680D
Trip Reclose Input1
680E
Trip Reclose Input2
680F
Trip Reclose Input3
6810
Trip Reclose Input4
6811
Trip Reclose Input5
6812
Trip Reclose Input6
6813
Trip Force 3-Pole
6814
Trip Pilot Priority
6815
Breaker Phase A Open
6816
Breaker Phase B Open
6817
Breaker Phase C Open
6818
Trip Events
6819
Reverse Fault Operand
681A
Trip Delay On Evolving Faults
681B
Reserved (5 items)
Open Pole Detect (1P) (Read/Write Setting)
6820
Open Pole Function
6821
Open Pole Block
6822
Open Pole Voltage Supervision
6823
Open Pole Current Pickup
6824
Open Pole Target
6825
Open Pole Events
6826
Open Pole Line XC0
6828
Open Pole Line XC1
682A
Open Pole Remote Current Pickup
682B
Reserved (5 items)
Pilot DUTT (1P) (Read/Write Setting)
6830
DUTT Function
6831
DUTT Seal In Delay
6832
DUTT 1P Number of Communication Bits
6833
DUTT RX1
6834
DUTT RX2
6835
DUTT RX3
6836
DUTT RX4
6837
DUTT 1P Target
6838
DUTT 1P Event
6839
Reserved (7 items)
Pilot PUTT (1P) (Read/Write Setting)
6840
PUTT 1P Scheme Function
6841
PUTT 1P Rx Pickup Delay
6842
PUTT 1P Seal In Delay
6843
PUTT 1P Number of Communication Bits
GE Multilin
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 65535
0 to 65.535
0 to 1
0 to 1
0 to 65535
0 to 1
0 to 30
0 to 2
0 to 1
300 to 9999.9
300 to 9999.9
0 to 30
0 to 1
0 to 1
0 to 65.535
0 to 2
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 65.535
0 to 65.535
0 to 2
D60 Line Distance Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F300
s
0.001
F001
---
1
F001
---
1
F102
---
1
F300
---
1
F102
pu
0.001
F001
---
1
F109
---
1
F102
ohms
0.1
F003
ohms
0.1
F003
pu
0.001
F001
---
1
F001
---
1
F102
s
0.001
F001
---
1
F198
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
s
0.001
F001
s
0.001
F001
---
1
F198
DEFAULT
0
0
0
0
0
B
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0 (Disabled)
0
0
0
0 (Disabled)
0
0 (Disabled)
50
0 (Self-reset)
0 (Disabled)
99999
99999
50
0
0 (Disabled)
0
0 (1)
0
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0
0
0 (1)
B-27