Belt Maintenance

Checking the Alternator Belt
Tension
Service Interval: After the first 10 hours
Every 200 hours
1. Apply 10 lb of force to the alternator belt, midway
between the pulleys.
2. If the deflection is not 3/8 in. (10 mm), loosen the
alternator mounting bolts (Figure 68).
Figure 68
1. Mounting bolt
3. Increase or decrease the alternator belt tension and
tighten the bolts.
4. Check the deflection of the belt again to ensure that
the tension is correct.
2. Alternator
Controls System
Maintenance
Adjusting the Control Lever
Neutral Interlock Switch
1. Stop the machine, move the control levers fully into
the neutral-locked position, set the parking brake,
and remove the ignition key.
2. Remove the bolts securing the front panel and
remove the panel (Figure 69).
1. Front panel bolts
3. Loosen the 2 screws securing the interlock switch
(Figure 70).
1. Control lever
2. Neutral interlock switch
42
Figure 69
Figure 70
3. Screws
4. 0.015 to 0.045 inch (0.4 to
1 mm)