4
Remove the four screws (D) from the left and right sensors.
Installation notes:
•
Before beginning the installation of the new left or right toner density sensor, note the 32-digit TPS value printed
on the barcode on the new FRU.
•
After installation, perform the TPS Setup. Enter the factory preset alignment number.
a
Enter the Diagnostics Menu:
1
Turn the printer off.
2
Press and hold 3 and 6.
3
Turn the printer on.
4
Release the buttons when the installed memory and processor speed displays.
b
Select TPS SETUP from Diag Menu, and press Select.
c
Select Right or Left, and press Select.
TPS Right 1‑16 or Left 1‑16 appears above a blinking 0 in the left position.
d
To enter a character or digit:
1
Press Left to decrease or Right to increase the blinking value.
2
Pause for several seconds without pushing any buttons. The blinking value becomes solid. If the value
is incorrect, then press Back to go back and reenter the number.
3
Continue until the last value is reached.
4
When the last of the 16 values is entered and becomes solid, TPS Right 17‑32 or TPS Left
17‑32 appears.
5
Continue entering and pausing.
e
After the 32nd number is entered and becomes solid, the number is automatically entered.
–
If the number is incorrect, then Checksum does not match appears, and the original screen
appears to reenter the value.
–
If the number is correct, then Saving changes to NVRAM appears.
Repair information
261
7527