Exhibit 3.0-5 The Email messages sent by the FibreBridge follow this format.
Subject: [The Type of Event that Occurred]
Message Body:
This is a status message from [FibreBridge name]. Identifying information as
well as the most recent entries from the event log appear below.
*************** Unit Information
Serial Number : [Serial Number]
IP Addresses:
[IP Address1]
[IP Address2]
***************
[Listing of the ten latest event log entries]
Exhibit 3.0-6 Events triggering an Email message, severity level and explanation
Severity
Event
Aborted Command
Device Down
Hardware Error
Medium Error
Temperature
Temperature
Unit Power On
Voltage
Critical
Voltage
Warning
Event Log Entries
Level
Warning
A SCSI command discovers a command has been aborted.
Warning
A target device has failed or become offline.
Critical
A SCSI command discovers an unrecoverable target device failure.
Warning
A command terminated with an error condition that may have been caused by a
flaw in the target device's physical medium or its recorded data.
Critical
Unit's internal temperature has increased to or is above the maximum operating
temperature or decreased to at or below the minimum operating temperature.
Warning
Unit's internal temperature has increased to or is within the unit's maximum
operating temperature less the unit's temperature warning offset or decreased to
or is within the unit's minimum operating temperature plus the unit's temperature
warning offset.
Info
The unit has been powered up.
A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
......
Level
VDDA (3.30V)
........ .......
Low
...............
High
A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
......
Level
VDDA (3.30V)
........ .......
Low
...............
High
***************
****************
Explanation
.......
VDDB (2.50V)
....................
.......................
5%
4%
....................
......................
8%
5%
.......
VDDB (2.50V)
....................
.......................
3%
3%
...................
....................
5%
3.5%
.
......
.....
VDDC (1.50V)
VDDD(1.35V)
..................
5%
4.5%
.................
5%
5%
......
.....
VDDC (1.50V)
VDDD(1.35V)
..................
3%
3%
.........., .....
3%
3%