7.7

Standard parameters

You can use the PNU to make parameter settings from the network.
The table below lists PNU numbers corresponding to parameter numbers.
Standard parameter examples are introduced below. Refer to the examples and make parameter settings.
The usable parameters depend on the inverter. Refer to the Instruction Manual (Detailed) of the inverter for details of the
parameters.
Representation of the PNU for standard parameters (Example: Pr.902)
P1902.1
Sub-Index Number
1000+Parameter Number
• Example of parameter list
PNU
Bit 0 of the ext-index number = "0"
P1000
Pr.0 Torque boost
P1001
Pr.1 Maximum frequency
P1002
Pr.2 Minimum frequency
P1003
Pr.3 Base frequency
P1004
Pr.4 Multi-speed setting (high speed)
P1005
Pr.5 Multi-speed setting (middle speed)
P1006
Pr.6 Multi-speed setting (low speed)
NOTE
• Write to Pr.77 and Pr.79 is not allowed from the network with FR-A8NP. (Read is allowed.)
• To read or write parameter of Pr.1000 or later, set Bit 0 of the ext-index number (extended parameter access) = "1".
(Refer to
page
Name
46)
Bit 0 of the ext-index number = "1"
Pr.1000
Pr.1001
Pr.1002 Lq tuning target current adjustment coefficient
Pr.1003 Notch filter frequency
Pr.1004 Notch filter depth
Pr.1005 Notch filter width
Pr.1006 Clock (year)
PPO TYPE SUPPORT SPECIFICATION
Data
type
Us16
Us16
Us16
Us16
Us16
Us16
Us16
7
65