 Error reset operation selection at inverter fault
An error reset command from communication option can be invalid in the External operation mode or PU operation mode.
Use Bit2 of Byte0 of Output Instance 20, 21, 126, or 129 and Class 0x29 Instance 1 Attribute 12 for error reset commands via
the network. (Refer to
page
Pr.
Name
349
Communication reset selection
45, 47, 49, 53, 63.)
Initial
value
0
Setting
range
0
Error reset is enabled independently of operation mode.
1
Error reset is enabled only in the network operation mode.
Function