6.2

Slave user parameter

By changing the slave user parameter value, you can use the byte swapping function (byte inversion function).
Setting "1" at Address H1 (Bit 0) enable the byte swapping function.
Since "
" is an unused bit, set "0".
Address
H0
For manufacturer setting (Always set "1".)
Bit 7
Bit 6
H1
• Example of when the byte swapping function is disabled (address H1 (Bit 0) = "0")
Master
• Example of when the byte swapping function is enabled (address H1 (Bit 0) = "1")
Master
The data is byte swapped in the slave to be a receiving/sending data.
Functions
Bit 5
Bit 4
Bit 3
Bit 2
Command request
WORD
WORD
H01
H02
H03
H04
Command request
WORD
WORD
H02
H01
H04
H03
slave
Bit 1
Bit 0
0:Byte swapping function disabled
1:Byte swapping function enabled
Command response
WORD
H05
slave
Master
Command response
WORD
H06
Master
WORD
H06
H07
H08
slave
WORD
H05
H08
H07
slave
PROFIBUS DEVICE DATA
6
39