Faults History Read - Mitsubishi Electric FR-A8NP Instruction Manual

Hide thumbs Also See for FR-A8NP:
Table of Contents

Advertisement

7.6.10

Faults history read

• Fault records of past eight faults occurred in the inverter can be read.
(For the data codes or details of fault records, refer to the Instruction Manual (Detailed) of the inverter.)
PNU
P947.1 to P947.8
Latest fault is read
P947.9 to P947.16
Second fault in past is read
P947.17 to P947.24
Third fault in past is read
P947.25 to P947.32
Forth fault in past is read
P947.33 to P947.40
Fifth fault in past is read
P947.41 to P947.48
Sixth fault in past is read
P947.49 to P947.56
Seventh fault in past is read
P947.57 to P947.64
Eighth fault in past is read
60
PPO TYPE SUPPORT SPECIFICATION
Item
P947.1
P947.2 to P947.8
P947.9
P947.10 to P947.16
P947.17
P947.18 to P947.24
P947.25
P947.26 to P947.32
P947.33
P947.34 to P947.40
P947.41
P947.42 to P947.48
P947.49
P947.50 to P947.56
P947.57
P947.58 to P947.64
Data definition
Data code of the fault record
All 0
Data code of the fault record
All 0
Data code of the fault record
All 0
Data code of the fault record
All 0
Data code of the fault record
All 0
Data code of the fault record
All 0
Data code of the fault record
All 0
Data code of the fault record
All 0
Data type
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16
AUs16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents