About setting
• Operation at an error occurrence
Fault description
Pr.502 setting
0
1
Communication line
2
3
0, 3
Communication option
itself
1, 2
When the communication returns to normal within the time period set in Pr.500, the communication option error (E.OP1) does not occur.
• Operation after the time in Pr.500 elapses after an error occurrence
Fault description
Pr.502 setting
0
1
Communication line
2
3
0, 3
Communication option
itself
1, 2
When an error occurs, the motor is decelerated or coasts to stop, and outputs the fault, independently of the Pr.500 setting.
Operation
Continued
Normal indication
Coast to stop
E. 1 lit
Decelerated to stop
E. 1 lit after stop
Operation
Coast to stop
E.OP1 lit
Decelerated to stop
E.OP1 lit after stop
Continues operation
Normal indication
with the Pr.779 setting.
Kept stopped
E.OP1 kept lit
Indication
Fault output
Not provided
Provided
Provided after stop
Indication
Fault output
Provided
Provided after stop
Not provided
Kept provided
INVERTER SETTING
4
27