Th Trim Throttle Trim; Th Subtrim Throttle Subtrim; Th Trimrate Throttle Trimrate - Ko Propo EX-2 Instruction Manual

Hide thumbs Also See for EX-2:
Table of Contents

Advertisement

TRIM Throttle Trim
Settings related to throttle control.
TH TRIM トリム
TH
TRIM   : 0
TH SUBT R I M 
TH TR I MRAT E  トリムレート : 5
▶ TH TRIM Throttle Trim
 
Modify the neutral position of the throttle.
▶ TH SUBTRIM Throttle Subtrim
 
Modify the overall throttle movement range.
▶ TH TRIMRATE Throttle Trimrate
 
Modify the amount of movement which corresponds to  
  one click of the throttle trim button.
▶ TH TRIM Throttle Trim
Adjusts the neutral/center position of the throttle
range.
【Setting Range】
TH TRIM : F50 〜 0 〜 B50
(Default : 0)
Setting adjustments prior to driving should be carried
P
out with the sub trim, not the trim.
The setting range cannot exceed what is set by [Throttle
P
Travel F] or [Throttle Travel B].
トリム
サブトリム : 0
▶ TH SUBTRIM Throttle Subtrim
Adjust the position of the overall throttle movement
range. Use this function when the neutral position
cannot be centered with only linkage adjustment.Also
refer to Trim and Sub Trim Operation. (p.15)
【Setting Range】
TH SUBTRIM : F80 〜 0 〜 B80
(Default : 0)
【Example】
The servo horn horn position can be adjusted by the
linkages, etc. when the servo is installed onto the
model, but in case the neutral position cannot be
centered, this function can be used to set it from the
transmitter.
If the sub trim value becomes large, adjust the servo
P
horn position or linkages so that the value becomes
closer to 0. If the sub trim value is too large, dead
zones could result and the servo may not operate at the
extremities of its movement range.
TH TRIMRATE Throttle Trimrate
Adjusts the amount of movement associated with
one click of the throttle trim button.
【Setting Range】
TH TRIM RATE : 1 〜 10
(Default : 5)
Although the amount of movement of one interval can be
P
adjusted, the lower the number the smaller the amount
of movement.
The overall number of intervals does not change, so a
P
change in trim rate will result in a change in the range in
which the trim can be used to make corrections.
If the trim rate is changed when the trim is already set,
P
the trim may be thrown off. If the trim setting is 0 then
this does not apply.)
Lower trim rates enable fine adjustments, but the effects
P
may not be apparent depending on the servo used. If
there is a lot of slop in the linkage or servo saver, fine
trim adjustments could cause the user to constantly
worry about the trim settings. In that case, please
reexamine the linkages, etc.
44

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ex-ii

Table of Contents