Reset Device Page
This page allows the user to reset the device. Click on the
Global Navigation Bar to open the page.
Figure 47.
There are three reset options available:
Reset Device Settings (Retains TCP/IP Settings) — Resets the settings associated
•
with input settings, the output image, EDID, and audio, and also includes presets and
auto memories (excludes Ethernet settings).
This is equivalent to the
NOTE: Ethernet and IP settings include the IP address, subnet mask, gateway
IP address, device name, DHCP setting, and port mapping.
•
Reset Device Settings and Delete Files (Retains TCP/IP Settings) — Resets
all settings on the device to factory defaults (deletes user files), except the Ethernet
settings.
This is equivalent to the
Reset All Settings and Delete Files — Resets all settings on the device to factory
•
defaults (deletes user files) including the Ethernet settings.
This is equivalent to the
NOTES:
•
•
To reset the device:
1.
Click the radio button of the desired reset option.
2.
Click the
3.
In the dialog box, click the
abort the reset.
Reset Device Page
E
}
ZXXX
E
}
ZY
E
}
ZQQQ
The default IP address is 192.168.254.254.
The default DHCP setting is Off.
button. A confirmation dialog box opens.
Apply
button to continue with the reset, or the
Yes
IN1606 Scaling Presentation Switcher • Internal Web Pages
Reset Device
SIS command.
SIS command.
SIS command.
button from the
button to
No