To ensure that the release of fibres from these R.C.F (Refractory
Ceramic Fibre) articles is kept to a minimum, during installation and
servicing we
recommend that you use a HEPA filtered vacuum to remove any dust
accumulated in and around the appliance before and after working on
the
appliance. When replacing these articles we recommend that the
replaced items are not broken up, but are sealed within heavy duty poly-
thene bags, clearly labelled as "RCF waste". RCF waste is classed as a
"stable", non reactive hazardous waste and may be disposed of at a
landfill licensed to accept such waste Protective clothing is not
required when handling these articles, but we recommend you follow
the normal hygiene rules of not smoking, eating or drinking in the work
area, and always wash your hands before eating or drinking.
5.4
REPLACING THE BATTERY IN THE IGNITION GENERATOR
The battery holder is located at the bottom R/H/S of the fire, unscrew
the cap, fit a new AA battery and re-fit the cap. See Fig. 7 below.
Fig. 7
Spark Generator
Battery Cap
AA Battery
IN THE EVENT OF THE FIRE FAILING TO LIGHT, PLEASE VISUALLY
CHECK FOR SPARKING AT THE IGNITION ELECTRODE ON THE PILOT.
IF NO SPARK IS PRESENT PLEASE REPLACE THE BATTERY AS
DETAILED ABOVE. SERVICE CALLS THAT ARE A DIRECT RESULT OF
FLAT BATTERIES WILL BE CHARGED FOR BY THE MANUFACTURER
AS THE BATTERY IN THE FIRE IS A CONSUMABLE ITEM THAT WILL
REQUIRE ROUTINE REPLACEMENT.