Flavel EmberGlow Classic FEMC00EN Installation, Maintenance & User Instructions page 21

Battery ignition radiant convector gas fire
Table of Contents

Advertisement

d)
Remove the valve retaining nut as shown below and disconnect the
wires to the microswitch as shown below in Fig. 18
Fig. 18
e)
Remove the thermocouple, which is a push fit into the rear of the control
valve.
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Remove the pilot retaining screws as described in section 4.2 d) &
fig. 15
b)
Disconnect the pipe pipe and push fit ignition lead
c)
Replacement new ODS in reverse order, and carry out a gas tightness
test.
Note : Prior to replacing the oxypilot on this product due to suspected
failure of the component, please remove all debris that has collected on
the lint guard of the oxypilot itself.
PARTS SHORTLIST
Replacement of any parts must be carried out by a competent person such as a
GAS SAFE registered gas installer. The part numbers of the replaceable parts are
as follows, these are available from specialist spares stockists whose details can
be found on our web site,www.bfm-europe.com, in the 'stockist' section.
Battery Ignition Generator
Coal set
Fuelbed
Gas valve (NG)
Rear Fibre board
B-43040
FC-P085332
ODS Pilot (NG)
B-123570
ODS Pilot (LPG) B-66920
B-135670
Gas Valve (LPG) B-137770
B-65320
Glass Assy (Front) SFA-085165
21
Valve retaining nut
and microswitch
wires
B-48360

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emberglow classic femc00ep

Table of Contents