Replacing The Batteries (Remote Control Models) - Flavel Decadence HE Installation, Maintenance & User Instructions

Inset live fuel effect gas fires
Table of Contents

Advertisement

5.3
Removing the Pilot Assembly
Note : Because this appliance is fitted with an atmosphere sensing 'Oxy-
Pilot' it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
5.3.1
Prepare work area (lay down dust sheets etc.)
5.3.2
Remove the burner assembly as described in section 5.1.
5.3.3
Loosen the pilot nut and remove the two screws retaining the pilot
assembly. Disconnect the thermocouple wires from the gas valve.
5.3.4
Re-assemble in reverse order, refit the burner heat shield then refit the
coals referring to section 3 for the correct coal / pebble layout. Refit the
glass panel and glass panel retaining trims. Refit the fascia and ashpan
cover.
5.4
Replacing the Batteries
5.4.1
Prepare work area (lay down dust sheets etc.)
5.4.2
Remove the trim / fret & ashpan cover.
5.4.3
The battery pack is located on the front of the valve, see page 32 for
position of battery cover on the control valve. Replace the batteries as
necessary.
5.4.4
The fender and ash-pan cover can now be re-positioned.
NB
The handset uses two AA sized alkaline batteries and should be
replaced by removing the cover on the rear of the handset.
ENSURE THE BATTERIES ARE CONNECTED TO THE CORRECT POLARITY
POSITVE (+), NEGATIVE (-)