Gas Tightness; Fitting The Battery - Flavel REGENT FRLC EN Series Installation And Maintenance Instructions Manual

Battery ignition live fuel effect convector gas fire
Table of Contents

Advertisement

Fig. 5
c)
Refit the dress guard.
2.5

GAS TIGHTNESS

a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply, fit the battery as described in section 2.6
then carry out a gas tightness test.
c)
Check that the gas pressure is 20.0 mbar (± 1.0 mbar), 8.0 in w.g. +/-
0.4 in w.g. with the main burner running.
d)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
2.6

FITTING THE BATTERY

a)
The battery holder is located at the bottom R/H/S rear of the fire,
unscrew the cap, fit the AA battery supplied in the loose items pack and
re-fit the cap. See fig. 6 overpage.