Fig. 14
If there is an extractor fan fitted in a joining room, then the spillage test must be
repeated with the fan switched on and running at maximum speed. All
interconnecting doors must be opened in accordance with the latest issue of BS
5440.
IF SPILLAGE IS DETECTED
The cause must be discovered and the fault corrected. If the fault cannot be cor-
rected disconnect the appliance from the gas supply and seek expert advice.
Possible causes of spillage from the appliance are:- chimney restriction, down
draught or insufficient air supply to the room.
e)
After ensuring that the fire is safe to use it should be left on "High"
position to fully warm up. During this time a slight odour may be
noticed, this is due to the "newness" of the fire and will soon disappear.
3.4
Final Check
a)
Recheck the operation of the fire on all settings.
b)
Make sure that the User knows how to operate the fire and refer them
to the User Book.
c)
Inform the User that the Model Number for ordering parts is shown on
the Rating plate. This is located on the back plate of the fire and can be
viewed by looking underneath the burner assembly. Inform the User the
fire should be serviced annually for continued safe operation.
d)
Hand this instruction booklet to the customer.
45 degrees
18
Smoke Match position -
Approximately 25mm
below and from left
hand edge of draught
diverter (viewed from
rear for clarity of image)
Smoke match holder to be
inserted at approximely 45
degree angle below side
trim