Configuring The Serveraid Bios - Nortel Application Server 53r 5300 Installation Manual

Nortel networks application server installation guide
Table of Contents

Advertisement

38 Hardware installation and configuration
25
Configuring the ServeRAID BIOS
Use this procedure to configure the ServeRAID BIOS.
Prerequisites
Procedure Steps
Step
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Copyright © 2007-2008 Nortel Networks
.
Select Exit Setup and select Yes when prompted for
confirmation.
The ServeRAID BIOS has been reset to the factory default settings.
Action
Reboot the server.
The server restarts and the following message displays:
Press CTRL-A for IBM ServeRAID Configuration
Utility
Press CTRL+A.
The IBM ServerRAID Configuration Utility screen appears.
Select SerialSelect Utility.
Select Controller Configuration.
Select Drives Write Cache.
Choose SATA Off, SAS Off.
Press Esc to return to the previous menu.
Select Yes to the Save Changes Made prompt.
Press Esc to return to the ServeRAID Configuration Utility
menu.
Select Array Configuration Utility.
Press C to create an array.
The Select drives to create Array window appears.
The Selected Drives list should be empty.
Highlight the first disk and press Ins.
The selected disk is added to the right window and the second
drive is now highlighted.
Press Ins to insert the second drive into the list.
The second drive is included in the Selected Drives list.
Press Enter.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300 01.04
4 November 2008
--End--

Advertisement

Table of Contents
loading

This manual is also suitable for:

Application server 5300

Table of Contents