Nortel Application Server 53r 5300 Installation Manual page 46

Nortel networks application server installation guide
Table of Contents

Advertisement

46 Platform software installation
2
3
4
5
6
7
8
9
10
Copyright © 2007-2008 Nortel Networks
.
Enter the VLAN number associated with the Service network.
This number must match the VLAN ID associated with the
Service network throughout the entire system configuration.
The system displays the following prompt:
Enter MACHINE logical IP address for VLAN
<SVC_VLAN_ID>:
Enter the machine logical IP address for the Service network.
The system displays the following prompt:
Enter default gateway IP address for VLAN
<SVC_VLAN_ID>:
Enter the default gateway IP address for the Service network.
The system displays the following prompt:
Enter netmask for VLAN <SVC_VLAN_ID>:
Enter the netmask for the Service network.
The system displays the following prompt:
Enter Maintenance VLAN ID (1-4094):
Enter the VLAN number associated with the Maintenance
network.
This number must match the VLAN ID associated with the
Maintenance network throughout the entire system configuration.
The system displays the following prompt:
Enter MACHINE logical IP address for VLAN
<MTC_VLAN_ID>:
Enter the logical IP address for the Maintenance network.
The system displays the following prompt:
Enter default gateway IP address for VLAN
<MTC_VLAN_ID>:
Enter the default gateway IP address for the Maintenance
Network.
The system displays the following prompt:
Enter netmask for VLAN <MTC_VLAN_ID>:
Enter the netmask for the Maintenance Network.
The system displays the following prompt:
Please choose the serial port to be used for system
console redirection:
Do one of the following:
Application Server 5300
Nortel AS 5300 Installation
NN42040-300 01.04
4 November 2008