or other water heater) is installed in the
same or an adjacent room.
To ensure safe operation, and to
prevent gases given off by these
appliances being drawn back into the
room, an underpressure of 4 Pa is the
maximum permissible.
Ventilation can be maintained by:
– air inlets in the external wall which
cannot be closed or blocked, or
– by fitting a window contact switch
which ensures that the appliance
can only be operated when the
window is open.
If in doubt, the advice of a competent
builder must be sought.
~
If more than one tumble dryer is
being installed using a joint ducting
system, each dryer must have its own
non-return flap to the joint ducting
system.
Otherwise the dryers could be
damaged, endangering their electrical
safety.
~
The fluff filter must be cleaned
regularly.
~
The dryer must not be used without
the fluff filter in place or if the fluff filter
is damaged in any way. Damaged
filters can cause operational faults and
blockages in the airways, the heating
elements and in the ducting. Fire
hazard!
In the event of a damaged filter, switch
the dryer off and replace the filter with a
new one.
Warning and Safety instructions
Accessories
~
Accessory parts may only be fitted
when expressly approved by Miele. If
other parts are used, guarantee,
performance and product liability
claims will be invalidated.
Disposing of your old
appliance
~
Before disposing of an old
washer-dryer and tumble dryer stack,
disable the washer-extractor door lock.
This way you will prevent children from
accidentally locking themselves in and
endangering their lives.
Miele cannot be held liable for
damage caused by non-compliance
with these Warning and Safety
instructions.