Insufficient quantity of electricity
Connected load:
Kränzle therm 895 ST: 400 V, 50 Hz (direction of rotation of no importance)
Kränzle therm 1165 ST: 400 V, 50 Hz (direction of rotation of no importance)
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.

Electrical connection

The machine is supplied with an electrical power cable with plug. The mains plug must
be fitted to a standard grounded socket with a 30 mA residual current operated device.
The socket must be protected with a 16A delay action fuse on the mains side. When
using an extension cable, this must have an earthed lead which is properly connected to
the socket. The conductors in the extension cable must have a minimum cross section of
1.5 mm². Plug connections must be of a spray-proof design, and may not be located on
a wet floor. With extension cables of more than 10 m the minimum cross section must
be 2.5 mm! When using a cable drum, always keep the cable wound as far as possible.
If there are too many collectors in your
proximity connected to the network at
the same time, the available voltage
and the current intensity may decline.
Consequently the motor of the high-pres-
sure cleaner does not start or even blows.
The power supply may also be insufficient
if the power cable is too long or too thin.
If extension cables are too long, this may
lead to a voltage drop causing malfunc-
tions or start-up difficulties.
11