Care And Maintenance (Weekly/Yearly); Changing The Oil - Kranzle therm 895 ST Operating Manual

High-pressure cleaner
Table of Contents

Advertisement

22
Care and Maintenance
The machine must be disconnected from the power supply when ser-
vicing work is being carried out. The main switch should be in positi-
on „0" and the plug out of the socket.
Weekly, or after approx. 40 hours of operation:
-
Check the oil level of the high pressure pump. If the oil level is too low, add oil until
the oil level is between the two markings on the oil sight glass.
Change the oil if it has a grey or whitish appearance. The oil should be
disposed of responsibly.
-
Check the water filter at the water inlet and in front of the float valve in the water
tank. Clean the filters if necessary.
Yearly, or after approx. 500 hours of operation:
-
Check and decalcify continous flow heater, if necessary.
-
Change the oil

Changing the oil:

Oil leakage: If oil leaks out, go to the nearest customer service (dea-
ler) immediately. (Environmental damages, transmission damages)
In case of increased humidity or fluctuations in temperature
development of condensed water is possible; if the oil turns grey,
you must change it at once.
First oil change after approximately 50
operating hours. Thereafter the oil should
be changed every 500 operating hours or
yearly.
Take the oil drainage hose, which is connec-
ted to the oil drainage screw from the inside
of the appliance.
Open the red oil filler plug at the top side of
the black oil housing.
Open the cap at the end of the hose. Drain
off the oil into an oil pan and dispose of it
responsibly. Close the end of the hose. Refill
with new oil.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Therm 1165 st

Table of Contents