Particular rules, directives and
inspections
Inspections performed by Kränzle
- measurement of earth line resistance
- measurement of voltage and current
- inspection of tension consistency with +/- 1530 V
- pressure check of heating coil at 300 bar
- visual and functional check as per the inspection sheet provided
- exhaust fume analysis (see test strips provided)
Guidelines for liquid sprayers
The machine conforms with the „Guidelines for liquid sprayers". These guidelines
are issued by the organisation of trade associations and may be obtained from Carl
Heymann-Verlag KG, Luxemburger Str. 49, 50939 Köln. These guidelines specify that
this machine is to be inspected by qualified personnel whenever necessary, but no less
than once every 12 months. These inspections must be recorded in the inspection log at
the end of this manual.
Pressure container and steam boiler directives
Kränzle high pressure cleaning equipment conforms to the pressure container and
steam boiler directive. No construction approval, notification of licence and takeover
inspection are required. The water capacity is less than 10 l.
Duties of owner
The owner is to ensure that all safety-relevant components are in a serviceable condition
before the sprayer is used. (e.g., safety valves, hose and electric cables, spray equip-
ment etc.)
Emission control legislation
With stationary installation, the emission levels of the machine must be checked once
a year by a qualified organisation or person according to German law. The first inspec-
tion must be carried out four weeks after the machine is commissioned. The owner is
responsible for having the inspection performed.