Excess Temperature Release - Kranzle therm 895 ST Operating Manual

High-pressure cleaner
Table of Contents

Advertisement

Troubleshooting
Displayed malfunctions
Display as follows
TARGET ACTUAL
Err
OFF
AUS
E7
Err
E2
FLA
E8
OIL
Actual
value
UES
Actual
value

Excess temperature release

As an additional safety device the appliance is equipped
with an excess temperature sensor inside the chimney. Should
the safety devices as e.g. the float monitoring device be defec-
tice and the burner continues to heat although the heating coil
does not conduct away heat a destruction of the heating coil
would be inevitable. As soon as the temperature inside the
chimney exceeds 260 °C the excess temperature release trig-
gers and cuts out the appliance.
The display of the excess temperature release is located on the
back of the switchbox inside the appliance.
RED:
Excess temperature released, let appliance cool down, no hot water operation possible
YELLOW: Appliance cooled down, activation of hot water opertion possible by pressing
the RESET-button.
ATTENTION !!!
Immediately contact service in case of recurrence!
Cause
Water temperature at heating
chamber outlet above 147 °C
Appliance has not been
operated for more than 20
minutes -> Safety cut-off
Temperature sensor defective
Warning
Flame monitoring;
No combustion was detected
by the flame sensor after 2s
Fuel level inside tank too low
Motor overload protection,
high-pressure pump has
triggered
Action
Operate appliance without
heating „Heating OFF" until the
temperature has dropped below
147°C. Switch main switch „OFF"
and then back „ON" again
Switch main switch „OFF" and
then back „ON" again.
Replace temperature sensor
Check flame sensor;
Check combustion system
Switch main switch „OFF" and
then back „ON" again.
Refill fuel
(Heating oil EL)
Check power supply,
remove extension cable,
nozzle clogged?
Switch main switch to „OFF" and
back to „ON" again
Überhitzung / Overheating
Heißwasserbetrieb erst
nach Abkühlung möglich.
Hot-water operation only possible
after cooling down phase.
Gerät abgekühlt, Heißwasserbetrieb
nach RESET wieder möglich.
Machine cooled down, hot-water
operation possible after RESET.
R
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Therm 1165 st

Table of Contents