Kranzle K 1050 P Operating Manual
Hide thumbs Also See for K 1050 P:

Advertisement

Operating manual
GB
High-pressure cleaner
K 1050 P
www.kraenzle.com

Advertisement

Table of Contents
loading

Summary of Contents for Kranzle K 1050 P

  • Page 1 Operating manual High-pressure cleaner K 1050 P www.kraenzle.com...
  • Page 2 Operating manual High-pressure cleaner K 1050 P Operating manual! Read and conform safety instructions before use! Keep instructions in a safe place for later use and pass them on to any future user.
  • Page 3 Your choice has fallen on an absolute quality product! adhere to the instructions may cause excessive wear or total Kränzle high pressure cleaners are characterized by their convenient and compact breakdown of the K 1050 P. design as well as their high suitability for everyday use. Warning!
  • Page 4: Safety Notes

    Safety notes Safety notes - This is prohibited! User operating the high pressure cleaner should wear the necessary protective clothing, i.e. waterproof clothing, rubber boots, safety goggles, headwear etc. It is prohibited to use the high pressure cleaner in close vicinity to people lacking When using high pressure water for clea- suitable protective clothing.
  • Page 5: Description Of High Pressure Cleaner

    Safety notes - This is prohibited! Description of high pressure cleaner Design The K 1050 P cleaner is a portable high pressure cleaner with an advanced arrangement system. Please see construction scheme for more details. Apply the safety catch on the safety trigger...
  • Page 6: General Rules

    The high pressure cleaner is designed for use in private environment only. 1. Kränzle high pressure cleaner Environmental, refuse disposal and water protection regulations K 1050 P must be observed! Inspections The high pressure cleaner must be inspected according to the “Guidelines for Liquid Spray Devices”...
  • Page 7: Functional Details

    Functional details Functional details Please note: Lack of water Insufficient quantity of electricity Lack of water occurs more often than you If there are too many collectors in your probably believe. The more powerful a high proximity connected to the network at the pressure cleaner is the greater is the danger same time, the available voltage and the that a lack of water occurs.
  • Page 8 When the trigger The high pressure hose and spray device which are part of the K 1050 P is released, the safety trigger gun closes and any further spraying of liquid from equipment, are made of high quality material and engineered to conform with the safety jet pipe is prevented.
  • Page 9: Putting Into Operation

    When carrying the K 1050 P, make sure to bear in mind the weight of the high pressure cleaner (see technical data). Neither set up or operate the K 1050 P in rooms where there is a risk of fire or explosion nor put it into puddles. Do not use the high pres- First pull back the retaining sleeve sure cleaner under water.
  • Page 10 Putting into operation Putting into operation Check water inlet filter for cleanliness Connect to circuit (see technical data). prior to putting the high pressure cleaner into operation. When inside filter is contaminated, remove filter and follow step 7.1. 7.1 If contaminated, remove the filter and Do not touch the mains plug or any live parts with wet or moist hands.
  • Page 11: Taking Out Of Operation

    Taking out of operation Small repairs - do it yourself Switch off the high pressure cleaner Problem No water from nozzle although the high pressure cleaner is running. 2. Cut off the water supply Cause Open the safety trigger gun catch briefly until the pressure is released Most likely the nozzle is blocked.
  • Page 12: Small Repairs - Do It Yourself

    Small repairs - do it yourself Small repairs - do it yourself Problem Problem Irregular jet from nozzle. After closing the safety trigger gun the high pressure cleaner keeps switching on and off. Cause Possible cause No. 1 Most likely the valves are soiled or sticky. Leckage.
  • Page 13: Ec Declaration Of Conformity

    Small repairs - do it yourself EC declaration of conformity We here by declare that the design of Problem the high pressure cleaners: Kränzle 1050 P After closing the safety trigger gun the high pressure cleaner keeps switching on and off. Nominal flow: 450 l/h Possible cause No.
  • Page 14: Kränzle Accessories

    Kränzle accessories Kränzle accessories Rotating washing brush BRUSH light 210 mm Stainless steel extension filth killer lance light Brush head ∅ 180 mm 400 mm Nozzle size 03 Nozzle size 2.5 mm Item no. 42.403-03 Item no. 12.800 Floor washer Round Cleaner UFO light ∅...
  • Page 15: Warranty

    Warranty Notes Warranty Our warranty obligation is understood to exclusively cover material and manufacturing defects, wear is not covered by warranty. The high pressure cleaner is to be operated in conformity with this Operating manual. The operating manual is deemed to be part of the warranty provisions. This warranty shall only apply on condition of proper use of original-Kränzle component parts and original-Kränzle replacement parts.
  • Page 16 Notes Notes...
  • Page 17 Josef Kränzle GmbH & Co. KG Rudolf-Diesel-Straße 20 89257 Illertissen (Germany) sales @ kraenzle.com Made Germany www.kraenzle.com...

Table of Contents