Electrical Connection - Kranzle W 11/135 Original Operating Manual

Hide thumbs Also See for W 11/135:
Table of Contents

Advertisement

W 11-135
230V/50Hz
W 13-230;
W 15-200;
W 19-160
400V/50Hz

Electrical connection

The machine is supplied with an electrical power cord with plug.
The mains plug must be fitted to a standard grounded socket with a
30mA residual current operated device. The socket must be protect-
ed with a 16A delay action fuse on the mains side.
KRÄNZLE W 11-135 = 230 Volt / 50 Hz
KRÄNZLE W 13-230 = 400 Volt / 50 Hz (phase-sequence not significant)
KRÄNZLE W 15-200 = 400 Volt / 50 Hz (phase-sequence not significant)
KRÄNZLE W 19-160 = 400 Volt / 50 Hz (phase-sequence not significant)
When using an extension cable, this must have an earthed lead which is prop-
erly connected to the socket. The conductors in the extension cable must have a
minimum cross section of 1.5 mm². Plug connections must be of a spray-proof
design, and may not be located on a wet floor.
(with extension cables of more than 10 m - 2.5 mm
CAUTION !
The use of extension cables which are too long may lead to malfunctions and start
up difficulty.