15)Dew Condensation Errors (Service Call 123); Dew Condensation - Oki C3530nMFP Maintenance Manual

Hide thumbs Also See for C3530nMFP:
Table of Contents

Advertisement

7.5.2.(15) Dew Condensation Errors (Service call 123)

(15-1) Dew Condensation

Confirmation Items
(15-1-1) Check of the connection
Connection of main board
(BLA PCB) and high-
voltage board
Connection of main board
(BLA PCB) and high-
voltage board
(15-1-2) Environment condition
Extreme change of
environment condition
43605601TH Rev. 1
Confirmation Tasks
Check whether 12-pole FFC is normally connected
with the HVOLT connector of main board (M32 PCB).
Check whether 12-pole FFC is normally connected
with the CN1 connector of high-voltage board.Check
whether incompletely connection and oblique insertion
occurs.
Check the wire-break by tester. By visual inspection,
check whether peeling off of coating occurs.
Is environment temperature changed from low to high
in a short time?(For example, move from cold storage
area to office environment.)
Oki Data CONFIDENTIAL
Action at NG
Reinsert the cable
normally.
Replace FFC with a
new one.
After moving the
printer to the new
environment for
about one hour till
it adapts to new
environment, turn
on the printer again.
Before turning
on the printer,
please check the
temperature of
sheet metal of rear
control panel and
inner sheet metal
by hand and check
that the difference
between the
above and room
temperature doesn'
t exist, then turn on
again.
202 /