Oki C3530nMFP Maintenance Manual page 184

Hide thumbs Also See for C3530nMFP:
Table of Contents

Advertisement

Confirmation Items
(3-2-4) Check the connection
Check the cable
connection.
Paper feed motor cable
Paper feed motor.
(3-2--5) Check the solenoid operation
Paper feed solenoid
Paper feed solenoid
(3-2--6) Check the connection
Paper feed solenoid cable Check the cable connection.By visual inspection,
Paper feed solenoid cable Check whether wire gnawing occurred during
43605601TH Rev. 1
Confirmation Tasks
By visual inspection, please check whether
incompletely connection and oblique insertion of
connector or defective cable assembly exists
Check whether wire gnawing occurred during
assembly of equipment.
Pull the HOP connector of main board (M32 PCB) out,
check the followings on the cable connector.
Short circuit between 1pin-FG
Short circuit between 2pin-FG
Short circuit between 3pin-FG
Short circuit between 4pin-FG
Pull the HOP connector of the main board (M32
PCB) out, check whether the resistance values
between 1pin-2pin and 3pin-4pin are about 3.5Wor
4.4Wrespectively on the cable side.
By using the motor clutch test function of the
maintenance utility, check whether paper feed solenoid
operates normally.Remove the sheet metal of the right
side in order to check whether the solenoid can be
seen.
Check whether the parts that may disturb the operation
of moving parts of the solenoid exist (cable etc).
please check whether incompletely connection and
oblique insertion of connector or defective cable
assembly exists.
assembly of equipment.
Pull the HSOL connector of main board (M32 PCB)
out, check the followings on the cable side.
Short circuit between 1pin-FG
Check whether the resistance value between 1pin-2pin
is about 82W with pulling the HSOL connector out.
Oki Data CONFIDENTIAL
Action at NG
Connect the cable
normally.Replace
the cable with a
new one.
Replace the cable
with a new one,
and reassemble
correctly.
Replace the paper
feed motor with a
new one.
Replace the main
board (M32 PCB)
or paper feed
solenoid with new
one.
Assemble normally.
Connect the cable
normally.Replace
the cable with a
new one.
Replace the cable
with a new one.
Replace the
solenoid ASSY
with a new one,
and reassemble
correctly.