8. Exit ZN conf.
0 = Before Entry (default)
1 = Except Entry
9. Entry clears conf.
This options selects whether a single (unconfirmed) alarm activation is remembered for the purposes of confir-
mation, after an entry door is open. This option has two settings:
0 = Reset Count
In this case, the confirmed alarm counter is reset to 0 as soon as an entry door is opened.
1 = Keep Count (default)
In this case, the confirmed alarm counter is maintained. If there is one alarm activation before the entry
door is opened, and then another activation after the entry delay expires, a confirmed alarm condition will
be generated, provided that both activations occur within the confirm time window.

Option 52 - Zones

Zones are programmed in menu 52. Each zone has a set of attributes as shown in the following table:
1
2
3
4
5
6
Note: Groups only appear if the Groups option is enabled (refer to option 63.1)
Selecting Zones
On entering the option, the first zone on the system is displayed; the zone address, function and group as-
signed are displayed on the top line, the descriptor is displayed on the bottom line.
From the display of the first zone, any zone on the system can be displayed by pressing the A or B keys or by
entering the address of a specific zone.
The zone is selected for programming by pressing the ent key; the first zone programming attribute 1=Func-
tion is displayed.
Attributes
The attributes can be stepped through by pressing the A or B keys or directly selected by pressing the at-
tribute number (1–6). Once the required attribute is on display, press the ent key to gain access for modifica-
tion.
Once the attribute has been assigned press the ent key to save the programming and return to the attribute
selection level.
Attributes
Function
Assigns Zone Type
Descriptor
SMS text - 16 characters max. alpha-numeric description
Soak Test
Zone monitored for 14 days max.
Omit enable
When enabled zone can be by-passed by authorized user
RF options
Zone set up with a wireless detector
Groups
Assigns a zone to a single group on the system
Table 22. Zone attributes
Description
69