Additional Functions

Code Tampers

When enabled (see Option 51, Parameter 14 = Lockouts), when 10 wrong codes are entered in succes-
sion, the keypad is locked. The lockout lasts for two minutes. After a further 10 wrong code entries, a tamper
is logged and a signal is given. The keypad is again locked out for two minutes.
NOTE: RF fobs can still operate.
Conversely, if a wrong tag is presented to a keyprox or an invalid RF fob is activated for a similar number of
attempts, the prox and receiver devices are locked out, but the keypads still operate.
If five wrong codes are entered from a keypad, followed by five wrong tags on a keyprox, both devices are
locked for two minutes.
After a further 10 wrong code entries, a tamper condition is logged and a signal is given. Both devices will be
locked out for two minutes.

Hot Keys

Three hot key functions are available on the keypads, by pressing a combination of two buttons. These func-
tions mimic the Panic, Fire and Assistance zone types.
On the RS485 keypads the following combination is used:
Fire:
* & 8
Panic:
* & 2
Assistance: * & 5
On the ECP keypads the following combination is used:
Fire:
3 & #
Panic:
* & #
Assistance: 1 & *